nuvcentercluster¶
-
nuvcentercluster.NUVCenterCluster(bambou.nurest_object.NUMetaRESTObject,):
VCenter Clusters.
Attributes¶
arp_reply
: Whether ARP Reply is enabled/disabledvrs_configuration_time_limit
: The maximum wait time limit in minutes to get VRS configured at cluster levelv_require_nuage_metadata
: Whether split-activation or not (Openstack/CloudStack)name
(Mandatory): Name of the Clustermanage_vrs_availability
: When this is set to true, the vCenter Integration Node will be responsible for marking a VRS Agent as available in the EAM framework. Until a VRS Agent has been marked as available, vCenter will not migrate VMs to the host running the VRS Agent and will not allow VMs to be powered on that host.managed_object_id
: VCenter Managed Object ID of the Cluster.last_updated_by
: ID of the user who last updated the object.last_updated_date
: Time stamp when this object was last updated.data_dns1
: Data DNS 1data_dns2
: Data DNS 2data_gateway
: Data Gatewaydata_network_portgroup
: Data Network Port Groupdatapath_sync_timeout
: Datapath Sync Timeoutscope
: Specifies if this cluster is in scope or not in scope.secondary_data_uplink_dhcp_enabled
: Enable DHCP on the secondary data uplink.secondary_data_uplink_enabled
(Mandatory): Enable secondary data uplinksecondary_data_uplink_interface
: Interface to use for the secondary data uplink. This interface can be a normal interface or a VLAN on an existing interface. Please read the VMware integration guide for more details.secondary_data_uplink_mtu
: Secondary data uplink MTUsecondary_data_uplink_primary_controller
: Secondary data uplink primary controller IPsecondary_data_uplink_secondary_controller
: Secondary data uplink secondary controller IPsecondary_data_uplink_underlay_id
: Secondary data uplink underlay IDsecondary_data_uplink_vdf_control_vlan
: The VLAN for the control communication with VSC on the secondary datapath interface, when VDF is enabled. This VLAN can not be used as a subnet VLAN in the VSD configuration.secondary_nuage_controller
: IP address of the secondary Controller (VSC)deleted_from_vcenter_data_center
: Set to true if the cluster is deleted from Vcentermemory_size_in_gb
: Memory in Gigabytesremote_syslog_server_ip
: Remote syslog server IPremote_syslog_server_port
: Remote syslog server portremote_syslog_server_type
: Remote syslog server type (UDP/TCP)generic_split_activation
: Whether split-activation is needed from VROseparate_data_network
: Whether Data will use the management network or notpersonality
: The personality of the VRS Agent, supported values when deploying through the vCenter Integration Node: VRS, VDF.description
: Description of the Clusterdestination_mirror_port
: Extra Vnic to mirror access portmetadata_server_ip
: Metadata Server IPmetadata_server_listen_port
: Metadata Server Listen Portmetadata_server_port
: Metadata Server Portmetadata_service_enabled
: Metadata Service Enablednetwork_uplink_interface
: Network Uplink Interface to support PAT/NAT with no tunnels on VRS-VMnetwork_uplink_interface_gateway
: Network Uplink Interface Gatewaynetwork_uplink_interface_ip
: Ip Address to support PAT/NAT with no tunnels on VRS-VMnetwork_uplink_interface_netmask
: Network Uplink Interface Netmaskrevertive_controller_enabled
(Mandatory): Enable revertive controller behaviour. If this is enabled, OVS will make its primary VSC as its master VSC once it is back up.revertive_timer
(Mandatory): A timer in seconds indicating after how long OVS should retry to connect to the primary VSC as its master after a failure.nfs_log_server
: IP address of NFS server to send the VRS lognfs_mount_path
: Location to mount the NFS serveragency_moid
: cluster in scope or not in scopemgmt_dns1
: DNS server 1mgmt_dns2
: DNS server 2mgmt_gateway
: Gateway for the IP addressmgmt_network_portgroup
: Management Network Port groupdhcp_relay_server
: To provide IP address of the interface from which you will connect to the DHCP relay servermirror_network_portgroup
: Mirror Port Group Namedisable_gro_on_datapath
: Disable GRO on datapathdisable_lro_on_datapath
: Disable LRO on datapathsite_id
: Site ID field for object profiles to support VSD Geo-redundancyallow_data_dhcp
: Whether to get the Data IP for the VRS VM from DHCP or staticallyallow_mgmt_dhcp
: Whether to get the management IP for the VRS VM from DHCP or statically.flow_eviction_threshold
: Flow Eviction Thresholdvm_network_portgroup
: VM Network Port Group Nameembedded_metadata
: Metadata objects associated with this entity. This will contain a list of Metadata objects if the API request is made using the special flag to enable the embedded Metadata feature. Only a maximum of Metadata objects is returned based on the value set in the system configuration.enable_vrs_resource_reservation
: Enable resource reservation on the VRS. When this is enabled, all memory and 100% of CPU resources allocated to the VRS will be reserved.entity_scope
: Specify if scope of entity is Data center or Enterprise levelconfigured_metrics_push_interval
: Configured VRS metrics push interval on VCINportgroup_metadata
: Port Group Meta datanova_client_version
: Nova client Versionnova_identity_url_version
: Keystone identity version to use for the Nova metadata configuration on the VRSnova_metadata_service_auth_url
: Nova metadata service auth urlnova_metadata_service_endpoint
: Nova metadata service endpointnova_metadata_service_password
: Nova metadata service passwordnova_metadata_service_tenant
: Nova metadata service tenantnova_metadata_service_username
: Nova metadata service usernamenova_metadata_shared_secret
: Nova metadata shared secretnova_os_keystone_username
: Keystone username used by novanova_project_domain_name
: Name of the project that the Nova service uses, can be determined from the nova.conf on the OpenStack controllernova_project_name
: Name of the default Nova project (example: services)nova_region_name
: Nova region namenova_user_domain_name
: Name of the user domain used by the Nova service, can be determined from the nova.conf on the OpenStack controllerupgrade_package_password
: Upgrade package password used for script based upgradesupgrade_package_url
: Upgrade package URLused for script based upgradesupgrade_package_username
: Upgrade package username used for script based upgradesupgrade_script_time_limit
: Time limit for the patch based upgrade functionality. If the upgrade process of a VRS has not returned a success or failure status within this time limit, the status will be changed to TIMEOUT. Specified in secondscpu_count
: The number of vCPUs that will be assigned to the VRS.creation_date
: Time stamp when this object was created.primary_data_uplink_underlay_id
: Primary data uplink underlay IDprimary_data_uplink_vdf_control_vlan
: The VLAN for the control communication with VSC on the primary datapath interface, when VDF is enabled. This VLAN can not be used as a subnet VLAN in the VSD configuration.primary_nuage_controller
: IP address of the primary Controller (VSC)vrs_password
: VRS password to be used by toolbox to communicate with VRSvrs_user_name
: VRS user name to be used by toolbox to communicate with VRSassoc_vcenter_data_center_id
: The ID of the vcenter to which this host is attachedassoc_vcenter_id
: ID of the associated VCenter.static_route
: static route to be configured in the VRSstatic_route_gateway
: Gateway for the static route given abovestatic_route_netmask
: Nova region namentp_server1
: IP of the NTP server 1ntp_server2
: IP of the NTP server 1mtu
: Maximum Transmission Unit for eth2 interfacemulti_vmssupport
: Whether Multi VM is to be used or notmulticast_receive_interface
: Multicast Receive Interfacemulticast_receive_interface_ip
: IP address for eth3 interfacemulticast_receive_interface_netmask
: Multicast Interface netmaskmulticast_receive_range
: Allowed Range to receive the Multicast traffic frommulticast_send_interface
: Multicast Send Interfacemulticast_send_interface_ip
: IP address for eth3 interfacemulticast_send_interface_netmask
: Multicast Interface netmaskmulticast_source_portgroup
: Multi Cast Source Port Group Namecustomized_script_url
: To provide a URL to install a custom app on VRSovf_url
: ovf urlavrs_enabled
: When enabled, the AVRS functionality will be enabled on the VRS during bootstrapping. This feature requires special AVRS licenses and specific configuration which is described in the product documentationavrs_profile
: The AVRS configuration profile that needs to be set up. This profile will configure the AVRS services so that it can support a certain type of performance.owner
: Identifies the user that has created this object.external_id
: External object ID. Used for integration with third party systems
Children¶
class | fetcher |
nuvcenterhypervisor.NUVCenterHypervisor | vcenter_hypervisors |
nupermission.NUPermission | permissions |
numetadata.NUMetadata | metadatas |
nuglobalmetadata.NUGlobalMetadata | global_metadatas |
nujob.NUJob | jobs |
nuvrsaddressrange.NUVRSAddressRange | vrs_address_ranges |
nuvrsredeploymentpolicy.NUVRSRedeploymentpolicy | vrs_redeploymentpolicies |
nuautodiscoverhypervisorfromcluster.NUAutoDiscoverHypervisorFromCluster | auto_discover_hypervisor_from_clusters |