nuvcenterdatacenter¶
-
nuvcenterdatacenter.NUVCenterDataCenter(bambou.nurest_object.NUMetaRESTObject,):
VCenter DataCenters.
Attributes¶
arp_reply: Whether ARP Reply is enabled/disabledvrs_configuration_time_limit: The maximum wait time limit in minutes to get VRS configured at cluster levelv_require_nuage_metadata: Whether split-activation or not (Openstack/CloudStack)name(Mandatory): Name of the Datacentermanage_vrs_availability: When this is set to true, the vCenter Integration Node will be responsible for marking a VRS Agent as available in the EAM framework. Until a VRS Agent has been marked as available, vCenter will not migrate VMs to the host running the VRS Agent and will not allow VMs to be powered on that host.managed_object_id: VCenter Managed Object ID of the Datacenter.last_updated_by: ID of the user who last updated the object.data_dns1: Data DNS 1data_dns2: Data DNS 2data_gateway: Data Gatewaydata_network_portgroup: Data Network Port Groupdatapath_sync_timeout: Datapath Sync Timeoutsecondary_data_uplink_dhcp_enabled: Enable DHCP on the secondary data uplink.secondary_data_uplink_enabled(Mandatory): Enable secondary data uplinksecondary_data_uplink_interface: Interface to use for the secondary data uplink. This interface can be a normal interface or a VLAN on an existing interface. Please read the VMware integration guide for more details.secondary_data_uplink_mtu: Secondary data uplink MTUsecondary_data_uplink_primary_controller: Secondary data uplink primary controller IPsecondary_data_uplink_secondary_controller: Secondary data uplink secondary controller IPsecondary_data_uplink_underlay_id: Secondary data uplink underlay IDsecondary_data_uplink_vdf_control_vlan: The VLAN for the control communication with VSC on the secondary datapath interface, when VDF is enabled. This VLAN can not be used as a subnet VLAN in the VSD configuration.secondary_nuage_controller: IP address of the secondary Controller (VSC)deleted_from_vcenter: Set to true if the datacenter is deleted from Vcentermemory_size_in_gb: Memory in Gigabytesremote_syslog_server_ip: Remote syslog server IPremote_syslog_server_port: Remote syslog server portremote_syslog_server_type: Remote syslog server type (UDP/TCP)generic_split_activation: Whether split-activation is needed from VROseparate_data_network: Whether Data will use the management network or notpersonality: The personality of the VRS Agent, supported values when deploying through the vCenter Integration Node: VRS, VDF.description: Description of the Datacenterdestination_mirror_port: Extra Vnic to mirror access portmetadata_server_ip: Metadata Server IPmetadata_server_listen_port: Metadata Server Listen Portmetadata_server_port: Metadata Server Portmetadata_service_enabled: Metadata Service Enablednetwork_uplink_interface: Network Upling Interface to support PAT/NAT with no tunnels on VRS-VMnetwork_uplink_interface_gateway: Network Uplink Interface Gatewaynetwork_uplink_interface_ip: Ip Address to support PAT/NAT with no tunnels on VRS-VMnetwork_uplink_interface_netmask: Network Uplink Interface Netmaskrevertive_controller_enabled(Mandatory): Enable revertive controller behaviour. If this is enabled, OVS will make its primary VSC as its master VSC once it is back up.revertive_timer(Mandatory): A timer in seconds indicating after how long OVS should retry to connect to the primary VSC as its master after a failure.nfs_log_server: IP address of NFS server to send the VRS lognfs_mount_path: Location to mount the NFS servermgmt_dns1: DNS server 1mgmt_dns2: DNS server 2mgmt_gateway: Gateway for the IP addressmgmt_network_portgroup: Management Network Port groupdhcp_relay_server: To provide IP address of the interface from which you will connect to the DHCP relay servermirror_network_portgroup: Mirror Port Group Namedisable_gro_on_datapath: Disable GRO on datapathdisable_lro_on_datapath: Disable LRO on datapathsite_id: Site ID field for object profiles to support VSD Geo-redundancyallow_data_dhcp: Whether to get the Data IP for the VRS VM from DHCP or staticallyallow_mgmt_dhcp: Whether to get the management IP for the VRS VM from DHCP or staticallyflow_eviction_threshold: Flow Eviction Thresholdvm_network_portgroup: VM Network Port Group Nameenable_vrs_resource_reservation: Enable resource reservation on the VRS. When this is enabled, all memory and 100% of CPU resources allocated to the VRS will be reserved.entity_scope: Specify if scope of entity is Data center or Enterprise levelconfigured_metrics_push_interval: Configured VRS metrics push interval on VCINportgroup_metadata: Port Group Meta datanova_client_version: Nova client Versionnova_identity_url_version: Keystone identity version to use for the Nova metadata configuration on the VRSnova_metadata_service_auth_url: Nova metadata service auth urlnova_metadata_service_endpoint: Nova metadata service endpointnova_metadata_service_password: Nova metadata service passwordnova_metadata_service_tenant: Nova metadata service tenantnova_metadata_service_username: Nova metadata service usernamenova_metadata_shared_secret: Nova metadata shared secretnova_os_keystone_username: Keystone username used by novanova_project_domain_name: Name of the project that the Nova service uses, can be determined from the nova.conf on the OpenStack controllernova_project_name: Name of the default Nova project (example: services)nova_region_name: Nova region namenova_user_domain_name: Name of the user domain used by the Nova service, can be determined from the nova.conf on the OpenStack controllerupgrade_package_password: Upgrade package password used for script based upgradesupgrade_package_url: Upgrade package URLused for script based upgradesupgrade_package_username: Upgrade package username used for script based upgradesupgrade_script_time_limit: Time limit for the patch based upgrade functionality. If the upgrade process of a VRS has not returned a success or failure status within this time limit, the status will be changed to TIMEOUT. Specified in secondscpu_count: The number of vCPUs that will be assigned to the VRS.primary_data_uplink_underlay_id: Primary data uplink underlay IDprimary_data_uplink_vdf_control_vlan: The VLAN for the control communication with VSC on the primary datapath interface, when VDF is enabled. This VLAN can not be used as a subnet VLAN in the VSD configuration.primary_nuage_controller: IP address of the primary Controller (VSC)vrs_password: VRS password to be used by toolbox to communicate with VRSvrs_user_name: VRS user name to be used by toolbox to communicate with VRSassociated_vcenter_id: The ID of the vcenter to which this host is attachedstatic_route: static route to be configured in the VRSstatic_route_gateway: Gateway for the static route given abovestatic_route_netmask: Nova region namentp_server1: IP of the NTP server 1ntp_server2: IP of the NTP server 1mtu: Maximum Transmission Unit for eth2 interfacemulti_vmssupport: Whether Multi VM is to be used or notmulticast_receive_interface: Multicast Receive Interfacemulticast_receive_interface_ip: IP address for eth3 interfacemulticast_receive_interface_netmask: Multicast Interface netmaskmulticast_receive_range: Allowed Range to receive the Multicast traffic frommulticast_send_interface: Multicast Send Interfacemulticast_send_interface_ip: IP address for eth3 interfacemulticast_send_interface_netmask: Multicast Interface netmaskmulticast_source_portgroup: Multi Cast Source Port Group Namecustomized_script_url: To provide a URL to install a custom app on VRSovf_url: ovf urlavrs_enabled: When enabled, the AVRS functionality will be enabled on the VRS during bootstrapping. This feature requires special AVRS licenses and specific configuration which is described in the product documentation.avrs_profile: The AVRS configuration profile that needs to be set up. This profile will configure the AVRS services so that it can support a certain type of performance.external_id: External object ID. Used for integration with third party systems
Children¶
| class | fetcher |
| nuvcentercluster.NUVCenterCluster | vcenter_clusters |
| nuvcenterhypervisor.NUVCenterHypervisor | vcenter_hypervisors |
| numetadata.NUMetadata | metadatas |
| nuglobalmetadata.NUGlobalMetadata | global_metadatas |
| nuvrsaddressrange.NUVRSAddressRange | vrs_address_ranges |
| nuvrsredeploymentpolicy.NUVRSRedeploymentpolicy | vrs_redeploymentpolicies |
| nuautodiscovercluster.NUAutoDiscoverCluster | auto_discover_clusters |
| nuautodiscoverhypervisorfromcluster.NUAutoDiscoverHypervisorFromCluster | auto_discover_hypervisor_from_clusters |