nuvcenter¶
-
nuvcenter.NUVCenter(bambou.nurest_object.NUMetaRESTObject,):
Represents a VCenter.
Attributes¶
eam_extension_name
: Name of the Nugae EAM Plugin registered with VCenter for the current instance of VCINarp_reply
: Whether ARP Reply is enabled/disabledvrs_configuration_time_limit
: The maximum wait time limit in minutes to get VRS configured at cluster levelv_require_nuage_metadata
: Whether split-activation or not (Openstack/CloudStack)name
(Mandatory): Name of the VCentermanage_vrs_availability
: When this is set to true, the vCenter Integration Node will be responsible for marking a VRS Agent as available in the EAM framework. Until a VRS Agent has been marked as available, vCenter will not migrate VMs to the host running the VRS Agent and will not allow VMs to be powered on that host.password
(Mandatory): Password for the VCenter userlast_updated_by
: ID of the user who last updated the object.last_updated_date
: Time stamp when this object was last updated.data_dns1
: Data DNS 1data_dns2
: Data DNS 2data_gateway
: Data Gatewaydata_network_portgroup
: Data Network Port Groupdatapath_sync_timeout
: Datapath Sync Timeoutsecondary_data_uplink_dhcp_enabled
: Enable DHCP on the secondary data uplink.secondary_data_uplink_enabled
(Mandatory): Enable secondary data uplinksecondary_data_uplink_interface
: Interface to use for the secondary data uplink. This interface can be a normal interface or a VLAN on an existing interface. Please read the VMware integration guide for more details.secondary_data_uplink_mtu
: Secondary data uplink MTUsecondary_data_uplink_primary_controller
: Secondary data uplink primary controller IPsecondary_data_uplink_secondary_controller
: Secondary data uplink secondary controller IPsecondary_data_uplink_underlay_id
: Secondary data uplink underlay IDsecondary_data_uplink_vdf_control_vlan
: The VLAN for the control communication with VSC on the secondary datapath interface, when VDF is enabled. This VLAN can not be used as a subnet VLAN in the VSD configuration.secondary_nuage_controller
: IP address of the secondary Controller (VSC)memory_size_in_gb
: Memory in Gigabytesremote_syslog_server_ip
: Remote syslog server IPremote_syslog_server_port
: Remote syslog server portremote_syslog_server_type
: Remote syslog server type (UDP/TCP)generic_split_activation
: Whether split-activation is needed from VROseparate_data_network
: Whether Data will use the management network or notpersonality
: The personality of the VRS Agent, supported values when deploying through the vCenter Integration Node: VRS, VDF.description
: Description of the VCenterdestination_mirror_port
: Extra Vnic to mirror access portmetadata_server_ip
: Metadata Server IPmetadata_server_listen_port
: Metadata Server Listen Portmetadata_server_port
: Metadata Server Portmetadata_service_enabled
: Metadata Service Enablednetwork_uplink_interface
: Network Uplink Interface to support PAT/NAT with no tunnels on VRS-VMnetwork_uplink_interface_gateway
: Network Uplink Interface Gatewaynetwork_uplink_interface_ip
: Ip Address to support PAT/NAT with no tunnels on VRS-VMnetwork_uplink_interface_netmask
: Network Uplink Interface Netmaskrevertive_controller_enabled
(Mandatory): Enable revertive controller behaviour. If this is enabled, OVS will make its primary VSC as its master VSC once it is back up.revertive_timer
(Mandatory): A timer in seconds indicating after how long OVS should retry to connect to the primary VSC as its master after a failure.nfs_log_server
: IP address of NFS server to send the VRS lognfs_mount_path
: Location to mount the NFS servermgmt_dns1
: DNS server 1mgmt_dns2
: DNS server 2mgmt_gateway
: Gateway for the IP addressmgmt_network_portgroup
: Management Network Port groupdhcp_relay_server
: To provide IP address of the interface from which you will connect to the DHCP relay servermirror_network_portgroup
: Mirror Port Group Namedisable_gro_on_datapath
: Disable GRO on datapathdisable_lro_on_datapath
: Disable LRO on datapathdisable_network_discovery
: disable Network Discovery (true - dont fetch portgroups from vcenter, false - fetch portgroups from vcenter)site_id
: Site ID field for object profiles to support VSD Geo-redundancyold_agency_name
: Old Agency Nameallow_data_dhcp
: Whether to get the Data IP for the VRS VM from DHCP or staticallyallow_mgmt_dhcp
: Whether to get the management IP for the VRS VM from DHCP or staticallyflow_eviction_threshold
: Flow Eviction Thresholdvm_network_portgroup
: VM Network Port Group Nameembedded_metadata
: Metadata objects associated with this entity. This will contain a list of Metadata objects if the API request is made using the special flag to enable the embedded Metadata feature. Only a maximum of Metadata objects is returned based on the value set in the system configuration.enable_vrs_resource_reservation
: Enable resource reservation on the VRS. When this is enabled, all memory and 100% of CPU resources allocated to the VRS will be reserved.entity_scope
: Specify if scope of entity is Data center or Enterprise levelconfigured_metrics_push_interval
: Configured VRS metrics push interval on VCINconnection_status
: VCenter connection status.portgroup_metadata
: Port Group Meta datahost_level_management
: Flag to say if host level management is enablednova_client_version
: Nova client Versionnova_identity_url_version
: Keystone identity version to use for the Nova metadata configuration on the VRSnova_metadata_service_auth_url
: Nova metadata service auth urlnova_metadata_service_endpoint
: Nova metadata service endpointnova_metadata_service_password
: Nova metadata service passwordnova_metadata_service_tenant
: Nova metadata service tenantnova_metadata_service_username
: Nova metadata service usernamenova_metadata_shared_secret
: Nova metadata shared secretnova_os_keystone_username
: Keystone username used by novanova_project_domain_name
: Name of the project that the Nova service uses, can be determined from the nova.conf on the OpenStack controllernova_project_name
: Name of the default Nova project (example: services)nova_region_name
: Nova region namenova_user_domain_name
: Name of the user domain used by the Nova service, can be determined from the nova.conf on the OpenStack controllerip_address
(Mandatory): IP Address of the VCenterupgrade_package_password
: Upgrade package password used for script based upgradesupgrade_package_url
: Upgrade package URLused for script based upgradesupgrade_package_username
: Upgrade package username used for script based upgradesupgrade_script_time_limit
: Time limit for the patch based upgrade functionality. If the upgrade process of a VRS has not returned a success or failure status within this time limit, the status will be changed to TIMEOUT. Specified in secondscpu_count
: The number of vCPUs that will be assigned to the VRS.creation_date
: Time stamp when this object was created.primary_data_uplink_underlay_id
: Primary data uplink underlay IDprimary_data_uplink_vdf_control_vlan
: The VLAN for the control communication with VSC on the primary datapath interface, when VDF is enabled. This VLAN can not be used as a subnet VLAN in the VSD configuration.primary_nuage_controller
: IP address of the primary Controller (VSC)vrs_config_id
: The ID of the template that this Port was created fromvrs_password
: VRS password to be used by toolbox to communicate with VRSvrs_user_name
: VRS user name to be used by toolbox to communicate with VRSuser_name
(Mandatory): User name of the VCenterstatic_route
: static route to be configured in the VRSstatic_route_gateway
: Gateway for the static route given abovestatic_route_netmask
: Nova region namentp_server1
: IP of the NTP server 1ntp_server2
: IP of the NTP server 1http_port
: Http proxy port for VCenterhttps_port
: Https proxy port of the VCentermtu
: Maximum Transmission Unit for eth2 interfacemulti_vmssupport
: Whether Multi VM is to be used or notmulticast_receive_interface
: Multicast Receive Interfacemulticast_receive_interface_ip
: IP address for eth3 interfacemulticast_receive_interface_netmask
: Multicast Interface netmaskmulticast_receive_range
: Allowed Range to receive the Multicast traffic frommulticast_send_interface
: Multicast Send Interfacemulticast_send_interface_ip
: IP address for eth3 interfacemulticast_send_interface_netmask
: Multicast Interface netmaskmulticast_source_portgroup
: Multi Cast Source Port Group Namecustomized_script_url
: To provide a URL to install a custom app on VRSauto_resolve_frequency
: Frequency at which VCenter issues are to be resolvedovf_url
: The url for the ovfavrs_enabled
: When enabled, the AVRS functionality will be enabled on the VRS during bootstrapping. This feature requires special AVRS licenses and specific configuration which is described in the product documentation.avrs_profile
: The AVRS configuration profile that needs to be set up. This profile will configure the AVRS services so that it can support a certain type of performance.owner
: Identifies the user that has created this object.external_id
: External object ID. Used for integration with third party systems
Children¶
class | fetcher |
nuvcenterdatacenter.NUVCenterDataCenter | vcenter_data_centers |
nupermission.NUPermission | permissions |
numetadata.NUMetadata | metadatas |
nuglobalmetadata.NUGlobalMetadata | global_metadatas |
nujob.NUJob | jobs |
nuvrsaddressrange.NUVRSAddressRange | vrs_address_ranges |
nuvrsredeploymentpolicy.NUVRSRedeploymentpolicy | vrs_redeploymentpolicies |
nuautodiscovereddatacenter.NUAutodiscovereddatacenter | autodiscovereddatacenters |